Get a Tailor-Made Power Solution.

  • Appliance Inlets: 16A, 32A, & 63A (110V, 240V, 415V)
  • Configurations: 3, 4, & 5 Pin options
  • 1, 2, 4, & 6 Gang versions 
  • Available in 4 enclosures sizes
  • Switched version also available.

Mobilbox can be configured with socket outlets, appliance inlets from 16A up to 125A, modules of 6 – 8 – 12 fuses and all standard switchgear equipment and terminals in the market to provide unique, flexible and custom designed solutions construction sites, workshops, marinas, and shipyards where external power distribution is required. 

  • All screws used in Mobilbox are INOX and stainless steel.
  • Mobilbox can easily be positioned wherever it is needed.
  • Mobilbox has high impact resistance.
  • Due to high resistance for environmental effects, Mobilbox can be used in both open and closed areas.
  • Top entry with 1xPG16/21 cable gland
  • Bottom entry with 2xPG16/21 cable glands
  • Installation up to 6 circuit breakers modules
  • Top entry with 1x PG16/21/29 and 2x PG16/21 cable glands
  • Bottom entry with 1x PG16/21/29 and 2x PG16/21 cable glands
  • Installation up to 11 circuit breakers modules
  • Top entry with 2xM20-2xM32/M40-2xM40/M50 cable glands
  • Bottom entry with 2xM20-2xM32/M40-2xM40/M50 cable glands
  • Installation up to 18 circuit breakers modules
  • Top entry with 2xM20/M25 – 3xM40/M50 cable glands
  • Bottom entry with 2xM20/M25 – 3xM40/M50 cable glands
  • Installation up to 13 circuit breakers modules
  • Top entry with 2xM20/M25 – 3xM40/M50 cable glands
  • Bottom entry with 2xM20/M25 – 3xM40/M50 cable glands
  • Installation up to 26 circuit breakers modules
  • 16A and 32A sockets can be used up to 7 pieces
  • For connection of fuses (MCB) and residual circuit breakers (RCD), it is possible to use 8-way fuse modules
  • Installation up to 6 circuit breaker modules
  • Installation up to 8 circuit breaker modules
  • Installation up to 12 circuit breaker modules

Ingress Protection: Specify your environment—IP44 for standard use or IP66 for high-moisture/dust environments. Socket Configuration: Detail your required Socket Outlets & Appliance Inlets (16A, 32A, or 63A). Protection Preferences: Confirm your RCD & MCB requirements for total site safety. Specify your requirements below, and consider the job done.

Name
Product to be suitable for
Ingress Protection Rating
Number of phases
Neutral available
Arrangement
Socket 1 Outlets Required
Socket 2 Outlets Required
Socket 3 Outlets Required
Socket 4 Outlets Required
Socket 5 Outlets Required
Socket 6 Outlets Required
Overall Disconnection Device
Over Current Outlet Type 1
Over Current Outlet Type 2
Over Current Outlet Type 3
Over Current Outlet Type 4
Over Current Outlet Type 5
Over Current Outlet Type 6
NOTE: All MCBs provided are type C unless otherwise requested